OPTIFLUX 1050
OPTIFLUX 1050
Electromagnetic flowmeter for basic applications with conductive liquids
- Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
- Extra isolation of electronics for use in high humidity areas
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
Shipping Policy
Return policy
Terms & Conditions
Overview
The OPTIFLUX 1050 is a cost-effective electromagnetic flowmeter (EMF) with lightweight wafer-style design. The meter is a very economical solution for simple applications with conductive liquids (≥ 5 μS/cm) involving low solid content (up to 10%). This particularly includes applications in water, wastewater, mobile applications, agriculture or firefighting where extremely high accuracy, extensive diagnostics or a wide range of communication options are not a priority. The extra isolation of the electronic device and housing makes this EMF also suitable for use in areas with extreme humidity.
The OPTIFLUX 1050 features a reinforced PFA liner and Hastelloy® electrodes that guarantee excellent chemical resistance and a large temperature range (up to +120°C / +248°F). The EMF has no internal moving parts, does not require maintenance and is insensitive to vibrations. It comes with current output (incl. HART®) or active pulse/frequency output and Modbus. A full on-site verification of the EMF without process interruption can be carried out using the OPTICHECK service tool.
Features & Options
Bi-directional flow measurement over a wide dynamic range
Lightweight and compact wafer-style ("sandwich") design for space saving installation
Reinforced PFA liner: Smooth surface, excellent chemical resistance
Full bore design: No moving parts, no wear, no pressure loss
Standard measurement accuracy: ±0.5% or ±1 mm/s of measured value (MV)
No maintenance required
On-site verification of flowmeter with OPTICHECK service tool
Typical applications
Water and wastewater industry
- Simple water applications (potable, raw, salt water, wastewater, heated and cooled water)
- Abstraction and irrigation
- Water circulation and treatment systems
Agricultural industry
- Sludge, manure, mud, slurry
Machinery and apparatus (OEM industry)
- Batching, dosing and mixing systems
- Compact and mobile skids
- Chemical handling systems
- Firefighting systems, foam mixing, control of sprinkler systems
- Filtration systems
- Pump wagons
Specifications
Depending on selected device configuration
General information
Product type | Flowmeter |
Product family name | OPTIFLUX |
Product positioning | For safety instrumented systems |
Measurement principle | Electromagnetic |
Contact to measured medium | Yes |
Measured media | Liquids |
Ambient temperature |
-40...+60°C / |
Nominal diameter / size | DN2.5...DN2000 / ⅒...80" |
Power supply (VAC) |
85...252 VAC |
Power supply (VDC) |
24 VDC |
Operating conditions
Process pressure | max. 40 barg/ 580 psig |
Process temperature | -40…+180°C/ -40…+356°F |
Materials
Liner | Ethylene tetrafluoroethylene (ETFE), Hard rubber, Perfluoroalkoxy alkane (PFA), Polytetrafluoroethylene (PTFE), Polyuretane (PUR) |
Process connections
Flange connections | EN (1092-1): DN2.5…2000 (larger on request) ASME (B 16.5): ⅒…80" (larger on request) JIS (B 2220): 2.5…1000A |
Pressure rating (EN 1092-1) | PN40 |
Pressure rating (JIS B 2220) | 20k |
Pressure rating (ASME B 16.5) | Cl 300#, Cl 600# |
Approvals/Standards
Certificates/Approvals Ex | ATEX, IECEx |
Certificates/Approvals Safety | SIL 2/3 |
NAMUR compliance | NE 107, NE 131, NE 21, NE 43, NE 53 |
Communication
Analogue outputs | 4…20 mA |
Discrete outputs | Frequency, Pulse, Status |
Digital outputs | HART® |
Accuracy
Accuracy (liquids) |
Measuring error ±0.2% of measured value (±1 mm/s) |
Accuracy (solids) |