OPTITEMP TT 51 C
OPTITEMP TT 51 C
Head-mounted temperature transmitter with universal dual input, galvanic isolation, HART® and SIL
Input: RTD, TC, mV, Ω
Output: 2-wire, 4…20 mA/HART®
Programmable via PC or HART® handheld communicator
Accuracy: ±0.05 %
Shipping Policy
Return policy
Terms & Conditions
The OPTITEMP TT 51 C is a universal, programmable high-performance 2-wire head-mounted temperature transmitter with HART® communication. The galvanically isolated dual input device works with RTD elements, thermocouple (TC) elements or other inputs (mV and Ω) in 2-, 3- or 4-wire circuit. It stands for proven stability, reliability as well as high accuracy and boasts a minimum measuring error of±0.05% of span in 5 years. The HART® transmitter offers extended diagnostic information (e.g. open or short circuit monitoring etc.). Its unique "SmartSense" function allows insulation resistance monitoring to prevent measuring errors.
The OPTITEMP TT 51 C is SIL2 approved (IEC 61508) and thus the ideal solution for use in Safety Instrumented Systems (SIS). The temperature transmitter is also available as intrinsically safe. As an added bonus, the ConSoft™ configuration software makes the OPTITEMP TT 51 start-up particularly simple. The transmitter is designed to be mounted in a "B connection head". A dedicated rail-mounted version for DIN rails is available with the OPTITEMP TT 51 R.
Features & Options
- Highly precise, completely universal digital device, with dual sensor input
- Configuration, installation and maintenance via software ConSoft, HART® protocol or EDD
- Best in class for long-term stability:±0.05% of span in 5 years
- Fast response time, high speed update (300 ms)
- High reliability due to 50-point linearization and sensor drift detection
- Sensor break monitoring and sensor error correction
- Isolation resistance monitoring (SmartSense): fail-safe up to 95% relative air humidity
- Rugged design: vibration-resistant up to 10 g
- Galvanic isolation: 1500 VAC
- Conforms to NAMUR in accordance with NE 43, NE 53, NE 89, NE 107
- Conforms to EMC in accordance with EN 61326 and NE 21
- Suitable for connection head B or larger
- SIL2 certified
- Optional rail mounting kit for installation on a DIN rail (in accordance with DIN EN 60715)
- Available as intrinsically safe: ATEX, IECEx (zone 0, 1, 2)
Specifications
Depending on selected device configuration
General information
Product type | Temperature transmitter |
Product family name | OPTITEMP |
Product positioning | With universal dual input, galvanic isolation, HART® and SIL |
Product variants |
|
Transmitter programmable | Yes |
Ambient temperature | -40…+85°C/ -40…+185°F |
Transmitter input | Potentiometer (Ω), Resistance (RTD), Thermocouple (TC), Voltage (mV) |
Galvanic isolation | Yes |
Galvanic isolation (VAC) | 1500 VAC |
Galvanic isolation (VAC) | 1500 VAC |
Power supply (VDC) | 10…36 VDC 10…30 VDC (Ex) |
RTD input | Cu10, Ni100, Ni1000, Ni120, Pt10, Pt100, Pt1000, Pt200, Pt50, Pt500 |
Potentiometer input (Ω) | 100…4000 Ω |
Voltage input (mV) | -10…+1000 mV |
RTD input / wiring | 2-wire, 3-wire, 4-wire |
TC Input | B, C, D, E, J, K, N, R, S, T |
Configuration method | HART handheld, PC/ConSoft software |
Transmitter mounting | Head-mounted |
Diagnostic functions | Isolation monitoring (SmartSense), Sensor backup function, Sensor break detection, Sensor drift detection, Sensor error correction, Sensor short circuit detection, Signal filtering function |
Approvals/Standards
Certificates/Approvals Ex | ATEX, IECEx |
Certificates/Approvals Safety | SIL 2 |
NAMUR compliance | NE 107, NE 21, NE 43, NE 53, NE 89 |
Communication
Analogue outputs | 4…20 mA |
Digital outputs | HART® |