OPTITEMP TT 32 R – Standard version
search
  • OPTITEMP TT 32 R – Standard version

OPTITEMP TT 32 R

OPTITEMP TT 32 R

Rail-mounted temperature transmitter with universal inputs and high galvanic isolation

Input: RTD, TC, mV, Ω

Output: 4-wire, 0/4…20 mA or 0…10 VDC

PC programmable

Accuracy: ±0.1%

 

Shipping Policy

 

Return policy

 

Terms & Conditions

The OPTITEMP TT 32 R is a universal, programmable 4-wire rail-mounted temperature transmitter. It works with RTD elements, thermocouple (TC) elements or other inputs (mV and Ω). The transmitter meets virtually any process requirement.

Thanks to its high galvanic isolation (4000 VAC), the OPTITEMP TT 32 R offers high safety. Its unique "SmartSense" function allows insulation resistance monitoring to prevent measuring errors. The temperature transmitter is available with current output (4…20 mA) or voltage output (0…10 VDC). Available as 24 VDC or 230 VAC version.

Features & Options

  • Completely universal digital device
  • Configuration without external power supply (via PC/software ConSoft)
  • With sensor break monitoring and sensor error correction
  • Isolation resistance monitoring (SmartSense): fail-safe up to 95% relative air humidity
  • Complete access to all functions during operation
  • Simple loop checking with calibrated output
  • Galvanic isolation: 4000 VAC
  • Designed for installation on a rail (in accordance with DIN EN 60715)
  • Available as 24 VDC or 230 VAC version

Specifications

Depending on selected device configuration

General information

Product type Temperature transmitter
Product family name OPTITEMP
Product positioning With universal inputs and high galvanic isolation
Product variants Standard: OPTITEMP TT 32 R
Transmitter programmable Yes
Ambient temperature -20…70°C/
-4…158°F
Transmitter input Potentiometer (Ω), Resistance (RTD), Thermocouple (TC), Voltage (mV)
Galvanic isolation Yes
Galvanic isolation (VAC) 4000 VAC
Galvanic isolation (VAC) 4000 VAC
Power supply (VAC) 90…250 VAC
Power supply (VDC) 20…30 VDC
RTD input Cu10, Ni100, Ni1000, Ni120, Pt100, Pt1000
Potentiometer input (Ω) 0…8000 Ω
Voltage input (mV) -10…+500 mV
RTD input / wiring 3-wire, 4-wire
TC Input B, C, E, J, K, L, N, R, S, T, U
Configuration method PC/ConSoft software
Transmitter mounting Rail-mounted
Diagnostic functions Isolation monitoring (SmartSense), Sensor break detection, Sensor error correction, Sensor short circuit detection

Approvals/Standards

NAMUR compliance NE 21, NE 43

Communication

Analogue outputs 0…10 VDC, 4…20 mA
OPTITEMP TT 32 R
Comments (0)
No customer reviews for the moment.