OPTIMASS 1400
search
  • OPTIMASS 1400
  • OPTIMASS 1400 C – Compact version with stainless-steel housing and hygienic clamp connection
  • OPTIMASS 1400

OPTIMASS 1400

OPTIMASS 1400

Coriolis mass flowmeter for universal applications and process control

Mass, density and volume flow of gases and liquids; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)

Also certified for hygienic use

Flange: DN15…100 / ½…4", max. PN100 / ASME Cl 600; many hygienic fittings

3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus, PROFINET, EtherNet/IP™, Bluetooth®

Process connection: DN25 PN40
Power supply: 100 - 230 V AC, (50/60Hz, 85-250V AC)
 

Shipping Policy

 

Return policy

 

Terms & Conditions

The OPTIMASS 1400 is a cost-effective twin straight tube Coriolis mass flowmeter for a wide range of standard applications with gases and liquids (up to 170,000 kg/h or 6,235 lb/min). The meter features Entrained Gas Management (EGMTM) for liquid applications and thus maintains operation even with entrained gas of up to 100%.

The OPTIMASS 1400 features an optimised flow splitter for minimum pressure loss and can be drained and cleaned easily. Next to flange process connections it supports a wide range of standard hygienic connections for food and beverage applications. Like with all other KROHNE Coriolis mass flowmeters there are no installation restrictions as the OPTIMASS 1400 is not affected by crosstalk/line vibrations and can thus be installed in series or in parallel. It is also approved for use in hazardous areas. The Coriolis mass flowmeter provides enhanced diagnostics (NE 107) and comes with various digital communication options. Via the OPTICHECK Flow Mobile app all device settings can be managed on-site via a secure Bluetooth® connection. In this way, a variety of commissioning tasks, e.g. zero calibration or configuration of diagnostics, can be done wirelessly.

Features & Options

  • Twin straight tube design
  • Entrained Gas Management (EGMTM): meter maintains operation with air or gas entrainments in the medium
  • Device commissioning, verification, diagnostics and monitoring via a secure wireless Bluetooth® connection (<20 m / 65.6 ft)
  • Fast and completely digital signal processing
  • Best-in-class price/performance ratio
  • High accuracy mass, density and volume flow measurement (±0.15% of MV)
  • Extensive sensor and process diagnostics (incl. NE 107)
  • Integrated temperature measurement
  • Optimised flow splitter for low pressure loss
  • Optional PED approved secondary pressure containment up to 100 barg / 1450 psig
  • Optional insulation, heating jacket or purge ports
  • No crosstalk: resistant to installation and process effects
  • On-site verification of flowmeter with OPTICHECK service tool

Typical applications

General

  • Standard process applications up to 130°C / 266°F
  • Measurement of liquids, gases and gas entrained liquids
  • Portable installations on trucks, rail tankers, portable rigs etc.
  • Applications with very low operating densities (<10 kg/m3)

Food and beverage industry

  • Measurement of flow, density, specific gravity in brewing processes
  • Flow measurement of beverages and fruit juices
  • Dairy products
  • Fat, oily and greasy products
  • Dosing of additive food components

Pharmaceutical industry

  • Batching, dosing, filling
  • Solvent extraction
  • Ultrapure water ring-main measurement

Chemical and other process industries

  • Bulk loading
  • Batching to reactors

Marine industry

  • Fuel consumption measurement

Pulp and paper industry

  • Batching and dosing of additives, bleaches and colorants

Water and wastewater industry

  • Flocculant dosing

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product family name OPTIMASS
Product positioning For universal applications and process control
Measurement principle Coriolis
Measured media Gases, Liquids

Operating conditions

Process pressure max. 100 barg/
1450 psig
Process temperature -40…+130°C/
-40…+266°F

Materials

Measuring tube Duplex stainless steel (1.4462/318)

Process connections

Flange connections EN (1092-1): DN15…100
ASME (B 16.5): ½…4"
JIS (B 2220): 15…80A
Pressure rating (EN 1092-1) PN100
Pressure rating (JIS B 2220) 20k
Pressure rating (ASME B 16.5) Cl 600#
Hygienic connections Clamp (DIN 32676): DN25, DN40, DN50, DN80
Clamp (ISO 2852): 25, 40, 51, 76.1
Tri-Clamp: 1", 1½", 2", 3"
Threaded ferrule (DIN 11851): DN25, DN40, DN50, DN80
Flange with groove (DIN 11864-2A): DN25, DN40, DN50, DN80
Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm, 76 mm

Approvals/Standards

Certificates/Approvals Nuclear Nuclear qualification on request (e.g. acc. to ASME III, RCC-M/E, etc.)
Certificates/Approvals Ex ATEX, cFMus, EAC Ex, IECEx, INMETRO, KCs, NEPSI, UKEX
Certificates/Approvals Hygienic 3A, EC 1935/2004, EHEDG, FDA
Certificates/Approvals Marine ABS, BV, CCS, CRS, DNV, IRS, KR, LR, NK, PRS, RINA, RS
Certificates/Approvals Others NACE

Communication

Analogue outputs 4…20 mA
Discrete outputs Frequency, Limit switches, Pulse, Status
Digital outputs Bluetooth, EtherNet/IP™, FOUNDATION™ fieldbus, HART®, Modbus RTU, Profibus-DP, Profibus-PA, PROFINET

OPTIMASS 1400

You might also like

Comments (0)
No customer reviews for the moment.