OPTIBAR DP 7060
OPTIBAR DP 7060
with diaphragm seal
Differential pressure transmitter for advanced applications and high temperatures
Continuous measurement of differential pressure, level, density and interface
Different diaphragm seals for corrosive, viscous or reducing media and vibration
Thread: ¼ NPT; Flange: DN50…100 / 2…4"
Measuring range: max. 16 psig / 232 psig; max. +400°C / +752°F
Shipping Policy
Return policy
Terms & Conditions
The OPTIBAR DP 7060 with single- or two-sided OPTIBAR DSD diaphragm seal is a pressure transmitter for differential pressure, level, density and interface measurement. It can be used in pressurised pipes, tanks and closed vessels. Its wide selection of inline or membrane diaphragm seals makes it particularly suitable for extremely aggressive and corrosive media, abrasive and highly viscous liquids or for hygienic applications. For applications with sudden pressure and temperature changes (up to +400°C / +842°F) or vibration, the pressure transmitter can be combined with one or two capillary diaphragm seals. The differential pressure device comes with a wide range of process connections. It has approvals for use in hazardous areas and comes with various digital communication options.
For Pressure operations the OPTIBAR DP 7060 is a differential pressure transmitter with integrated absolute pressure measurement. It offers a high degree of modularity for various flow, hydrostatic level or process pressure applications. For DP flow measurements it can be perfectly combined with the KROHNE primary elements (e.g. orifice plates or pitot tubes). Equipped with diaphragm seals, it is the right choice for hydrostatic level, interface, density or demanding DP process applications. Featuring a quick response time of just 125 ms, the DP transmitter offers high accuracy and measurement stability under all process conditions.
KROHNE is the only manufacturer of process instrumentation to carry out a total 3D linearization of its differential pressure transmitter. For a robust and accurate differential pressure measurement, even under changing process conditions, each OPTIBAR DP 7060 differential pressure transmitter is linearized in all three dimensions during calibration: differential pressure, ambient temperature and static pressure are taken into account in combination. Since the full specified operating range is covered, an utmost stable and accurate measurement under all process conditions is guaranteed.
Features & Options
- Available with a wide range of diaphragm seals (single- or two-sided)
- Vibration resistant with capillary tube attachment
- Available wetted materials:
- Wetted materials: Stainless steel (1.4404 / 316L), tantalum, Hastelloy®C-276, titanium grade 2, Monel®400, duplex, 1.4404 / 316 L with gold coating
- PFA coating: FDA and EC1935/2004 conform, complies with Ex requirements, suitable for vacuum and aseptic applications, temperature limit up to +260°C / 500°F (up to +200°F / +392°F for vacuum applications)
- PTFE coating: suitable for vacuum applications up +200°C / +392°F, complies Ex requirements, FDA and EC1935/2004 conform
- With OPTIBAR DP 7060 high-performance transmitter:
- Unique 3D linearization: compensates for all influencing factors at virtually all possible combinations
- Very good repeatability and long-term stability of the measuring signal
- Integrated absolute pressure measurement for lowest possible influence of static pressure changes on the signal
- Ex ia, Ex d approvals
- SIL 2/3
Typical applications
General
- Differential pressure and level applications with aggressive, corrosive, highly viscous, solidifying or abrasive products
- High temperature applications
- Pressure and level measurement in vibrating environments
- Detection of liquid-liquid-interfaces
- Dead-zone-free arrangement of measuring points under particularly hygienic conditions
Specifications
Depending on selected device configuration
General information
Product type | Level transmitter |
Product family name | OPTIBAR |
Product positioning | For advanced applications |
Measured media | Liquid/liquid interface, Liquids |
Operating conditions
Process pressure | max. 400 bar/ 5802 psi |
Process temperature | -50…+400°C/ -58…+752°F |
Approvals/Standards
Certificates/Approvals Ex | ATEX, IECEx, NEPSI |
Certificates/Approvals Hygienic | 3A, EC 1935/2004, EHEDG, FDA |
Certificates/Approvals Safety | SIL 2/3 |
Communication
Analogue outputs | 4…20 mA |