OPTIFLEX 3200 C–Compact version with polished Ø8 / 0.32 mm single rod probe
search
  • OPTIFLEX 3200 C–Compact version with polished Ø8 / 0.32 mm single rod probe

OPTIFLEX 3200

OPTIFLEX 3200

Guided radar (TDR) level transmitter for liquids with hygienic requirements

Continuous measurement of level and interface in small and narrow vessels

Conform to FDA, EC1935/2004, EHEDG

Measuring range: 0.6…4 m / 2…13 ft

-50…+150°C / -58…+302°F; -1…40 barg / -14.5…580 psig

 

Shipping Policy

 

Return policy

 

Terms & Conditions

The OPTIFLEX 3200 is a 2-wire guided radar level transmitter based on the Time Domain Reflectometry (TDR) technology. It is designed for the measurement of level and interface in the food, beverage and pharmaceutical industry. The TDR is insensitive to steam, foam or condensation and suitable for a large variety of liquids with hygienic requirements. The wetted parts have a gap-free hygienic design that ensures simple and reliable cleanability (CIP/SIP). Dedicated industry-specific probes and process connections as well as various converter and electronic versions are available to suit every installation and facilitate device access.

Features & Options

  • Hygienic probes and process connections for the food and beverage as well as pharmaceutical industry
  • Suitable for SIP (Sterilisation In Place) and CIP (Cleaning In Place)
  • Insensitive to steam, foam and condensation
  • Measurement of interfaces starting at 50 mm / 1.97"
  • Various converter and electronic versions to facilitate access to the device:
    • Available as compact version (C) or with remote converter (F) up to 100 m / 328 ft
    • Horizontal or vertical housing to suit every installation
  • Converter is rotatable and removable under process conditions and compatible with all previous Guided Radar (TDR) level transmitters made by KROHNE
  • Cast stainless steel or aluminium housing
  • ±2 mm /±0.08" accuracy
  • Real-time clock for event logging
  • 3-year warranty

Typical applications

General

  • Level and interface measurement of liquids in hygienic applications with finished and raw products
  • Applications with storage tanks, vessels, mixers and containers

Food and beverage industry

  • Fruit extract, compote
  • Raw milk, cheese
  • Beer, wine
  • Yeast
  • Fruit juice, tomato sauce, soup
  • Vegetable oil, palm oil
  • Alcohols, purified water

Pharmaceutical industry

  • Solvents, alcohols, aqueous solutions
  • Slightly corrosive acids, alkalis
  • Chlorobenzene, chloroform
  • Vaccines, plasma

Specifications

Depending on selected device configuration

General information

Product type Level transmitter
Product family name OPTIFLEX
Product positioning For liquids with hygienic requirements
Product variants
  • OPTIFLEX 3200 C: Compact housing
  • OPTIFLEX 3200 F: Field
Measurement variables Dielectric constant, Distance, Level, Mass, Volume
Measurement principle Guided radar
Level measurement type Continuous measurement
Contact to measured medium Yes
Interface measurement Yes
Redundancy No
Measured media Liquid/liquid interface, Liquids
Measuring range (liquids) 0.6…4 m /
1.97…13.12 ft
Probe length units to display m/ft
Probe length 0.6...4 m /
1.97...13.12 ft
Probe diameter
  • Single rod Ø8 mm / 0.32"

Operating conditions

Process pressure -1…40 barg /
-14.5…580 psig
Process temperature -50…+150°C /
-58…+302°F

Materials

Gaskets Ethylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM/FPM), Kalrez® 6221, PEEK, Polytetrafluoroethylene (PTFE), Ceramic
Wetted parts Austenitic stainless steel (1.4404/316L)

Process connections

Hygienic connections Collar ferrule with nut (DIN 11851): DN25, DN40, DN50
Collar ferrule with nut (SMS 1147): 38 mm, 51 mm
Clamp (DIN 32676): DN25, DN40, DN50
Clamp (ISO 2852): 25, 38, 51
Tri-Clamp®: 1", 112", 2"

Approvals/Standards

Certificates/Approvals Ex ATEX, cQPSus, IECEx, INMETRO, NEPSI
Certificates/Approvals Hygienic EC 1935/2004, EHEDG, FDA
Certificates/Approvals Safety SIL 2
Ingress protection IP66/68, NEMA4X/6P

Communication

Analogue outputs 4…20 mA
Discrete outputs Relay
Digital outputs HART®

Accuracy

Accuracy (liquids) ±2 mm /
±0,08"