OPTIWAVE 5400

OPTIWAVE 5400

Radar (FMCW) level transmitter for liquids in basic process applications

Continuous, non-contact level measurement in closed tanks or in the open air

24 GHz radar, Horn or Drop antennas

Measuring range: 0…100 m / 328 ft

-50…+130°C / -58…+266°F; -1…16 barg / -14.5…232 psig

   

 

Shipping Policy

 

Return policy

 

Terms & Conditions

The OPTIWAVE 5400 is a 2-wire 24 GHz radar (FMCW) level transmitter for liquids in basic process applications. It is particularly designed for continuous, non-contact level measurement in the chemical, petrochemical, power as well as oil and gas industry. It can be equipped with a PP Drop antenna for condensing atmospheres and corrosive media but features also Metallic Horn antennas. Due to its high dynamic range, the 24 GHz radar can measure distances up to 100 m / 328 ft.

The OPTIWAVE 5400 provides accurate readings even in processes with fast changing levels, in closed tanks or in the open air (dams, rivers etc.). This level transmitter can replace radars in basic applications requiring higher accuracy. It offers flange or thread connections as well as optional antenna extensions to suit any nozzle length. It is approved for hazardous areas and comes with extensive device diagnostics (acc. to NE 107) as well as HART®7 communication.

Features & Options

  • 2-wire, loop-powered, with HART®7
  • PP Drop antenna:
    • Insensitive to condensation
    • Small beam angle (5° with DN150 / 6″ Drop antenna)
    • Ellipsoidal shape and smooth surface to minimise scaling
    • PP flange plate protection and cladded antenna extensions for corrosive media
    • New DN100 / 4″ Drop antenna for distances up to 80 m / 262.5 ft
  • 316L Metallic Horn antenna with optional purging system
  • TBM (Tank Bottom Management) ensures reliable measurement even in empty tanks:
    • dedicated algorithms to filter and compensate for irregular radar wave reflections that occur at tank bottom when the vessel is empty
    • allows for quick and easy commissioning of tanks regardless of their size, material or geometry
  • ±2 mm / ±0.08″ accuracy
  • Antenna extensions to suit any nozzle length
  • Empty tank spectrum function eliminates false reflections caused by tank internals
  • Large choice of flange and thread connections
  • Large, backlit LCD screen with 4-button keypad for operation with bar magnet; no need to open the housing cover
  • PACTware™, HART® DD and DTM provided free of charge with full functionality
  • Extensive device diagnostics acc. to NAMUR NE 107
  • SIL 2/3 certified for safety-related applications
  • 3-year warranty

Typical applications

General

  • Level measurement in storage, process or batch tanks (max. 100 m / 328 ft) and open air applications (dams, rivers etc.)
  • Storage and process tanks requiring high accuracy
  • Processes with fast changing levels (≤60 m/min / 196.85 ft/min)

Chemical Industry

  • Alcohols e.g. methanol, ethanol
  • Solvents, acids, bases
  • Phosphorus
  • Additives
  • Condensates
  • Lime slurry

Petrochemical Industry, Oil and Gas Industry

  • Fuels
  • Hydraulic oils and other hydrocarbons

Power Industry

  • Process and cooling water

Specifications

Depending on selected device configuration

General information

Product type Level transmitter
Product family name OPTIWAVE
Product positioning For liquids in basic process applications
Measurement variables Distance, Level, Mass, Reflection, Volume
Measurement principle Radar
Level measurement type Continuous measurement
Contact to measured medium No
Interface measurement No
Redundancy No
Measured media Liquids, Pastes, Slurries
Measuring range (liquids) 0…100 m/
0…328 ft
Ambient temperature -40…+80°C/
-40…+176°F

Operating conditions

Process pressure -1…16 barg/
-14.5…232 psig
Process temperature -50…+130°C/
-58…+266°F

Materials

Gaskets Ethylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM/FPM), Kalrez® 6375
Wetted parts Austenitic stainless steel (1.4404/316L), Polypropylene (PP)

Process connections

Flange connections EN (1092-1): DN40…200
ASME (B 16.5): 1½…8"
JIS (B 2220): 40…200A
Pressure ratings EN (1092-1): PN40
ASME (B 16.5): Cl 300#
JIS (B 2220): 10k
Pressure rating (EN 1092-1) PN40
Pressure rating (JIS B 2220) 10k
Pressure rating (ASME B 16.5) Cl 300#
Thread connections Male:
G1, G1½
1 NPT, 1½ NPT

Approvals/Standards

Certificates/Approvals Ex ATEX, cQPSus, EAC Ex, IECEx, KCs, NEPSI
Certificates/Approvals Others CRN / ASME B31.3, NACE, WHG
Certificates/Approvals Safety SIL 2/3
Ingress protection IP66/68, NEMA4X/6P
NAMUR compliance NE 107, NE 21, NE 43, NE 53

Communication

Analogue outputs 4…20 mA
Digital outputs FOUNDATION™ fieldbus, HART®, Profibus-PA

Accuracy

Accuracy (liquids) ±2 mm/