OPTIMASS 6400 C Food
search
  • OPTIMASS 6400 C Food

OPTIMASS 6400 Food & Beverage Version

OPTIMASS 6400

Food & Beverage version

Coriolis mass flowmeter for advanced food and beverage applications

High accuracy mass flow and concentration measurement in advanced dosing applications and process control

With Entrained Gas Management (EGM™) for applications with aerated products (e.g ice cream, dairy products etc.)

Also suitable for dosing of gases or cryogenic media (e.g in carbonation or food freezing processes)

FDA, EC1935/2004 conform; 3A, EHEDG certified

Process connection: DN25 PN40
Power supply: 100 - 230 V AC, (50/60Hz, 85-250V AC)
 

Shipping Policy

 

Return policy

 

Terms & Conditions

The OPTIMASS 6400 is the standard high performance Coriolis mass flowmeter for the process industry. The twin bent tube meter offers superior performance and high accuracy in virtually any application: From process control in (petro)chemical applications to concentration measurements in the food and beverage industry to custody transfer filling and transport measurements in the oil and gas industry. Its high-end options also make the OPTIMASS 6400 the optimum device for cryogenic media like Liquefied Natural Gas (LNG) with temperatures down to -200°C / -328°F as well as applications involving high operating temperatures (up to 400°C / 752°F) or pressures (up to 200 barg / 2900 psig).

The OPTIMASS 6400 features Entrained Gas Management (EGMTM) for liquid applications and thus maintains operation even with entrained gas of up to 100%. The meter has various approvals for hazardous areas and is also suitable for use in Safety Instrumented Systems (SIL 2/3). It comes with extensive diagnostic functions (NE 107) and various digital communication options. Via the OPTICHECK Flow Mobile app all device settings can be managed on-site via a secure Bluetooth® connection. In this way, a variety of commissioning tasks, e.g. zero calibration or configuration of diagnostics, can be done wirelessly.

Features & Options

  • Twin bent tube design
  • Entrained Gas Management (EGMTM): maintains operation with air or gas entrainments in the medium
  • The only Coriolis mass flowmeter on the market allowing secure wireless access via Bluetooth® or remotely via HART® in safety-related applications
  • Device commissioning, verification, diagnostics and monitoring via a secure wireless Bluetooth® connection (<20 m / 65.6 ft)
  • SIL 2/3 certified up to DN200 / 8″
  • Partial proof test possible with PTC (Proof Test Coverage) of up to 82%
  • Fast and completely digital signal processing
  • Integrated temperature measurement
  • Optimised flow splitter for minimum pressure loss
  • High accuracy mass, density and volume flow measurement (optional ±0.05% of MV)
  • Highest OIML accuracy class of 0.3 for custody transfer (CT)
  • Extensive sensor and process diagnostics (incl. NE 107)
  • Available in three different sensor materials (incl. Duplex and alloy 22)
  • Many options (heat tracing, purge port etc.)
  • Self draining when mounted vertically
  • No crosstalk: resistant to installation and process effects
  • On-site verification of flowmeter with OPTICHECK service tool possible

Typical applications

General

  • Liquids with transient gas entrainment
  • Cryogenic or high temperatures (-200…+400°C /-328…+752°F)
  • Super critical gases
  • Custody transfer (CT)
  • Safety Instrumented Systems (SIL 2/3)

Chemical and other process industries

  • Concentration and density measurement
  • Bulk loading
  • Batching and blending to reactors
  • Hydrocarbon cracking

Oil and gas industry

  • Metering skids, bulk loading, pipeline transfer
  • "Bypass" density measurement
  • Liquefied Natural Gas (LNG)
  • Bulk loading
  • In-line density measurement
  • Multiphase measurement in upstream applications

Food and beverage industry

  • Batching, dosing, filling
  • Mass flow measurement of ice cream and milk (e.g. at the raw milk reception)
  • Measurement of flow, density, specific gravity in brewing processes
  • Dosing of hop extract
  • Measurement of Brix, density and flow in fruit juices
  • Dosing of natural oils, grease, vegetables (e.g. spinach) etc.
  • CO2 injection in soft drink production

Pharmaceutical industry

  • Batching, dosing, filling
  • Solvent extraction

Marine industry

  • Bunkering and fuel consumption measurement

Pulp and paper industry

  • Additives, bleaches and colorants
  • Crystallizing, solidifying and cryogenic products

Specifications

Depending on selected device configuration

General information

Product type Flowmeter
Product family name OPTIMASS
Product positioning For advanced process and custody transfer (CT) applications
Measurement principle Coriolis
Measured media Gases, Liquids

Operating conditions

Process pressure max. 200 barg/
2900 psig
Process temperature -200…+400°C/
-328…+752°F

Materials

Measuring tube Austenitic stainless steel (1.4404/316L), Austenitic alloy (2.4602/Alloy 22), Duplex stainless steel (1.4462/318)

Process connections

Flange connections EN (1092-1): DN10…300
ASME (B 16.5): ½…12"
JIS (B 2220): 10…100A
Pressure rating (EN 1092-1) PN160
Pressure rating (JIS B 2220) 20k
Pressure rating (ASME B 16.5) Cl 150#
Hygienic connections Clamp (DIN 32676): DN15, DN25, DN40, DN50, DN80, DN100
Clamp (ISO 2852): 25, 40, 51, 76.1, 101.6
Tri-Clamp: ½", ¾", 1", 1½", 2", 3", 4"
Threaded ferrule (DIN 11851): DN15, DN25, DN40, DN50, DN80, DN100
Flange with groove (DIN 11864-2A): DN15, DN25, DN40, DN50, DN80, DN100
Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm, 76 mm, 101.6 mm

Approvals/Standards

Certificates/Approvals Ex ATEX, cFMus, EAC Ex, IECEx, INMETRO, KCs, NEPSI, UKEX
Certificates/Approvals Hygienic 3A, EC 1935/2004, EHEDG, FDA
Certificates/Approvals Marine ABS, BV, CCS, CRS, DNV, IRS, KR, LR, NK, PRS, RINA, RS
Certificates/Approvals Others NACE
Certificates/Approvals Safety SIL 2/3

Communication

Analogue outputs 4…20 mA
Discrete outputs Frequency, Limit switches, Pulse, Status
Digital outputs Bluetooth, EtherNet/IP™, FOUNDATION™ fieldbus, HART®, Modbus RTU, Profibus-DP, Profibus-PA, PROFINET
OPTIMASS 6400 Food & Beverage Version

You might also like

Comments (0)
No customer reviews for the moment.